Google

Monday, August 17, 2009

Port speed and duplex auto negotiation.

Note: This section is only applicable for 10/100/1000 Mbps (1000BASE-T) NICs, and not 1000BASE-X NICs.

Table 1—Autonegotiation Valid Configuration

Configuration NIC (Speed/Duplex)

Configuration Switch (Speed/Duplex)

Resulting NIC Speed/Duplex

Resulting Catalyst Speed/Duplex

Comments

AUTO

AUTO

1000 Mbps, Full-duplex

1000 Mbps, Full-duplex

Assuming maximum capability of Catalyst switch, and NIC is 1000 Mbps, full-duplex.

1000 Mbps, Full-duplex

AUTO

1000 Mbps, Full-duplex

1000 Mbps, Full-duplex

Link is established, but the switch does not see any autonegotiation information from NIC. Since Catalyst switches support only full-duplex operation with 1000 Mbps, they default to full-duplex, and this happens only when operating at 1000 Mbps.

AUTO

1000 Mbps, Full-duplex

1000 Mbps, Full-duplex

1000 Mbps, Full-duplex

Assuming maximum capability of NIC is 1000 Mbps, full-duplex.

1000 Mbps, Full-duplex

1000 Mbps, Full-duplex

1000 Mbps, Full-duplex

1000 Mbps, Full-duplex

Correct Manual Configuration

100 Mbps, Full-duplex

1000 Mbps, Full-duplex

No Link

No Link

Neither side establishes link, due to speed mismatch

100 Mbps, Full-duplex

AUTO

100 Mbps, Full-duplex

100 Mbps, Half-duplex

Duplex Mismatch 1

AUTO

100 Mbps, Full-duplex

100 Mbps, Half-duplex

100 Mbps, Full-duplex

Duplex Mismatch 1

100 Mbps, Full-duplex

100 Mbps, Full-duplex

100 Mbps, Full-duplex

100 Mbps, Full-duplex

Correct Manual Configuration2

100 Mbps, Half-duplex

AUTO

100 Mbps, Half-duplex

100 Mbps, Half-duplex

Link is established, but switch does not see any autonegotiation information from NIC and defaults to half-duplex when operating at 10/100 Mbps.

10 Mbps, Half-duplex

AUTO

10 Mbps, Half-duplex

10 Mbps, Half-duplex

Link is established, but switch does not see Fast Link Pulse (FLP) and defaults to 10 Mbps half-duplex.

10 Mbps, Half-duplex

100 Mbps, Half-duplex

No Link

No Link

Neither side establishes link, due to speed mismatch.

AUTO

100 Mbps, Half-duplex

100 Mbps, Half-duplex

100 Mbps, Half-duplex

Link is established, but NIC does not see any autonegotiation information and defaults to 100 Mbps, half-duplex.

AUTO

10 Mbps, Half-duplex

10 Mbps, Half-duplex

10 Mbps, Half-duplex

Link is established, but NIC does not see FLP and defaults to 10 Mbps, half-duplex.

 

 

No comments: